Building Regulations Part G: Non-HRB Domestic Compliance Guide for Small Practices

Approved Document G — Sanitation, Hot Water Safety and Water Efficiency · Building Safety Act 2022 · Non-HRB projects

Summary

What the Building Safety Act requires for Part G on non-HRB domestic jobs

Requirements G1–G6 run from wholesome water supply through to food preparation areas. For small practice work the two recurring items are G2 water efficiency — every new dwelling (including conversions creating dwellings) needs a water efficiency calculation showing ≤125 l/person/day, tightened to 110 where the local plan requires it — and G3 hot water supply and systems, which governs unvented cylinders.

G3 is safety-critical: an unvented cylinder stores water under pressure, and the stacked safety devices (thermostat, thermal cut-out, temperature/pressure relief valve) plus a correctly detailed discharge pipe are what stand between a fault and a steam explosion. Installation is notifiable and must be by an operative holding a recognised G3 qualification, with the certificate retained.

As Principal Designer (BSA), your coordination evidence is the water calculation at design stage, the cylinder location and discharge route resolved on drawings (not left to site), and the commissioning certificates in the handover pack.

Key design risks and evidence needed (RIBA Stages 2–4)

Standards and references you should be citing

Vented vs unvented hot water: the compliance difference

AspectVented cylinderUnvented cylinder (G3)
Safety devicesOpen vent to atmosphereThermostat + thermal cut-out + T&P relief valve, all factory-fitted
InstallerCompetent plumberG3-qualified registered installer; work is notifiable
Discharge pipeworkNot applicableD1/D2 pipe sized and routed to safe visible termination, shown on drawings
Evidence to logCommissioning recordG3 certificate, discharge route drawing, commissioning record

Common pitfalls that catch out sole practitioners

Frequently asked questions

Does a domestic extension need a water efficiency calculation?

No — G2 water efficiency applies to new dwellings, including those formed by material change of use. An extension to an existing house does not trigger the calculation, though any new sanitary installations must still meet G1, G3 and G4 as applicable.

Can any plumber install an unvented cylinder?

No. G3 installation is notifiable building work and should be carried out by an installer holding a recognised unvented hot water qualification, typically registered with a competent person scheme. Keep the certificate — it is the compliance evidence for one of the few genuinely dangerous systems in a house.