Building Regulations Part L: Non-HRB Domestic Compliance Guide for Small Practices

Approved Document L — Conservation of Fuel and Power (Volume 1: Dwellings) · Building Safety Act 2022 · Non-HRB projects

Summary

What the Building Safety Act requires for Part L on non-HRB domestic jobs

For new dwellings, compliance runs through SAP 10: the dwelling must beat its notional counterpart on primary energy, carbon emissions and fabric energy efficiency, meet minimum fabric standards, and be delivered with a BREL (Building Regulations England Part L) report signed off with photographic evidence of foundations/substructure, external wall construction, insulation continuity at junctions, airtightness details and services — geolocated or otherwise verifiable photos taken during construction.

For extensions — the small practice bread and butter — the standard route is elemental: new thermal elements at the limiting U-values, openings at ≤25% of the extension's floor area (plus any covered-over openings), with SAP-based area-weighted or whole-dwelling trade-offs available when the client wants more glass. That trade-off calculation is design evidence: commission it at Stage 3, not after the glazing order.

The photographic evidence regime is where the BSA dutyholder mindset lands hardest. Someone must plan which junctions get photographed before they are covered up. As Principal Designer (BSA), building the photo schedule into the specification — and holding the images in the project record — is precisely the 'plan, manage, monitor' duty in action.

Key design risks and evidence needed (RIBA Stages 2–4)

Standards and references you should be citing

Limiting fabric values for extensions (AD L Vol 1, 2021)

ElementNew element in an extensionNotes
External wall0.18 W/m²KThermal element U-value
Pitched roof (insulation at ceiling)0.15 W/m²K0.15 also for flat roofs
Floor0.18 W/m²KCalculated to BS EN ISO 13370 with P/A ratio
Windows / rooflights1.4 W/m²K (or WER band B)Rooflights assessed in the vertical plane
Doors1.4 W/m²KIncludes glazed doors
Glazed area≤25% of extension floor area + covered openingsExceed via area-weighted or SAP trade-off

Common pitfalls that catch out sole practitioners

Frequently asked questions

What photographic evidence does Part L 2021 actually require?

For new dwellings, the BREL report process expects date- and location-referenced photographs of each plot showing foundations/substructure, wall construction and insulation, roof insulation, junction detailing, airtightness measures and building services, taken before covering up. For the Principal Designer, the practical task is writing the photo checklist into the contract documents and collecting the images into the golden-thread record.

Can a domestic extension have more than 25% glazing?

Yes, via compensating measures: an area-weighted U-value calculation showing the extension performs no worse than a notional compliant one, or a full SAP comparison of the existing dwelling plus extension against the dwelling plus notional extension. Commission the calculation at design stage and keep it — it is the compliance basis for the whole elevation.

Does Part L apply to a like-for-like window replacement?

Yes — replacement windows are controlled fittings and must achieve 1.4 W/m²K or WER band B, alongside the Part F trickle vent requirements. FENSA-type self-certification or Building Control notification applies either way.